LAN cables
CAT 7 Flex / S-STP - FRNC
Application:
Data cable for local area networks (LAN) up to 600 MHz. By using of flexible conductors suitable e.g. for device connection or as patch cable for rack-wiring.
Construction:
Conductor:
- tinned stranded copper wire
Structure of conductor:
- AWG26/7
Core insulation:
- Cell PE, Foam Skin
First twisting:
- cores to pairs
Pair screen:
- AL-Foil (PimF)
Twisting:
- pairs to cable rope
Total screen:
- tinned copper braid
Jacket:
- FRNC (LSZH)
Technical characteristics:
Impedance:
- 100 +/- 15 Ohm @ 100 MHz
Capacity:
- approx. 45 pF/m
Insulation resistance:
- > 2 GOhm x km at + 20°C
Rel. propagation velocity:
- approx. 0,76 c
Attenuation: (db/100m)
- 1 MHz: 2,7
- 10 MHz: 8,0
- 100MHz: 26,1
- 300MHz:45,7
- 600MHz:66,2
Temperature range:
- static: -20°C to + 60°C
- dynamic: -5°C to + 50°C
Bending radius:
- while installation: min. 8xAD
- after installation: min. 5xAD
Packaging:
rings, reels
Product range
CAT 7 Flex / S-STP - FRNC
| Order no. | dimension | O.D. | weight | co.-weight |
|---|---|---|---|---|
| (AWG) | (ca. mm) | (kg/km) | (kg/km) | |
| 5308267H0 | 4x2xAWG 26/7 | 6,2 | 42 | 22 |