- installation
- halogen free
- FRNC
- RoHS
- REACH
- CE
Application / Description
For professional installations in broadcasting stations and studios, where safety regulations concerning the behaviour in case of fire acc. to VDE 0472 part 804 test kind C (IEC 60332-3) have to be observed. Due to the high flexibility the handling resembles that of PVC types. Please consider the small outside diameters as well as the light weigth of this series.
Product range
Order-No. | Dimension | Cross section qmm | O.D. approx. mm | weight kg/km | Cu-weigth kg/km |
---|---|---|---|---|---|
950201400 | 1 x 2 x 0,14 qmm | 0,14 | 4,70 | 33,0 | 17,0 |
950401400 | 2 x 2 x 0,14 qmm | 0,14 | 7,50 | 73,0 | 35,0 |
950801400 | 4 x 2 x 0,14 qmm | 0,14 | 8,90 | 102,0 | 55,0 |
951201400 | 6 x 2 x 0,14 qmm | 0,14 | 10,30 | 139,0 | 80,0 |
951601400 | 8 x 2 x 0,14 qmm | 0,14 | 12,00 | 180,0 | 105,0 |
952001400 | 10 x 2 x 0,14 qmm | 0,14 | 12,90 | 219,0 | 123,0 |
952401400 | 12 x 2 x 0,14 qmm | 0,14 | 13,40 | 251,0 | 142,0 |
▲ | compare |
Construction / audio
Conductor
- tinned stranded copper wire
Structure of conductor
- 7 x 0,16 mm
Cross section
- 0,14 qmm
AWG
- 26
number of cores
Core insulation
- Cell-PE
Colour sequence
number of pairs
Pre-twisting
- 2 cores to a pair
Element shield
- tinned copper spiral shield
Element jacket
- TPE-E, numbered
Twisting
- Pairs in layers with filler string where applicable, overall glass silk taping
Overall shield
- tinned copper braid shield
Outer jacket
- FRNC
Outer jacket colour
- grey, RAL 7001
Technical characteristics
Temperature range
- static: -25 °C to +70 °C
- dynamic: -5 °C to +70 °C
Bending radius
- > 12 x O.D.
Operating capacity (C/C)
- approx. 55 pF/m
Operating capacity (C/S)
- approx. 95 pF/m
Characteristic impedance
- 0,3 Mhz: 110
Ohm ±10%
1,0 Mhz: 110 Ohm ±10%
3,0 Mhz: 110 Ohm ±10%
10,0 Mhz: 105 Ohm ±10%
Attenuation
- 0,3 Mhz: approx. 1,3
db/100m
1,0 Mhz: approx. 2,3 db/100m
3,0 Mhz: approx. 5,8 db/100m
10,0 Mhz: approx. 12,5 db/100m
Cross-talk attenuation
- 0,3 Mhz: approx. 80
db/100m
1,0 Mhz: approx. 75 db/100m
3,0 Mhz: approx. 65 db/100m
10,0 Mhz: approx. 60 db/100m
Testing voltage (C/C)
- 250 V
Testing voltage (C/S)
- 1.000 V
Packaging
Rings, ReelsLower and upper lengths according to availability. Special packaging on request.
Add-on information
- Flame retardant acc. to DIN VDE 0472 part 804 testing C / IEC 332.3
- zero halogen acc. to DIN VDE 0472 part 815 / IEC 754-1
- no acid gas emission acc. to DIN VDE 0472 part 813 / IEC 754-2
- low smoke emission in case of fire