UL-LiYY   UL AWM 2464/2517-10002, unshielded
  • installation
  • mobile
  • RoHS
  • REACH
  • CE

UL-LiYY

UL AWM 2464/2517-10002, unshielded

Application / Description

For connections in all fields of measuring and control engineering as well as in the signal and impulse technology. UL-specifications have to be matched for products which are exported to the american market. Because of SR-PVC is used as core-insulation, suitable for insulation displacement connectors (IDC). The outer jacket is to a very large extent resistant against oils, petrol- and weather-proof as well as  uv-resistant by special-pvc.

Product range

Order-No.   Dimension   O.D. approx. mm weight kg/km Cu-weigth kg/km skinning tool (core)   skinning tool (jacket)  
095022809 2 x AWG 28 3,50 15,3 1,8 20310 40025
095032809 3 x AWG 28 3,70 17,3 2,6 20310 40025
095042809 4 x AWG 28 3,90 19,1 3,5 20310 40025
095062809 6 x AWG 28 4,40 23,9 5,2 20300 / 20310 40025
095082809 8 x AWG 28 4,80 28,5 6,9 20300 40025
095102809 10 x AWG 28 5,40 34,2 8,6 20300 40025
095022609 2 x AWG 26 3,70 16,0 2,8 20310 40025
095032609 3 x AWG 26 3,80 19,0 4,1 20310 40025
095042609 4 x AWG 26 4,10 22,0 5,5 20310 / 30900 40025
095062609 6 x AWG 26 4,80 30,0 8,2 20300 / 30900 40025
095082609 8 x AWG 26 5,10 35,0 11,0 20300 / 30160 40025
095102609 10 x AWG 26 5,80 42,0 13,7 20300 / 30160 40025
095022409 2 x AWG 24 4,00 17,0 4,3 20310 / 30900 40025
095032409 3 x AWG 24 4,20 25,0 6,4 20310 / 30900 40025
095042409 4 x AWG 24 4,50 29,0 8,6 20300 / 30900 40025
095062409 6 x AWG 24 5,30 37,0 12,8 20300 / 30160 40025
095082409 8 x AWG 24 5,50 45,0 17,1 20300 / 30160 40025
095102409 10 x AWG 24 6,30 53,0 21,4 20300 / 30160 40025
095022009 2 x AWG 20 4,60 28,0 11,0 20300 / 30900 40025
095032009 3 x AWG 20 4,90 36,0 16,4 20300 / 30900 40025
095042009 4 x AWG 20 5,40 47,0 21,9 20300 / 30160 40025
095062009 6 x AWG 20 6,10 64,0 32,8 20300 / 30160 40025
095082009 8 x AWG 20 6,80 79,0 43,7 20300 / 30160 40025
095102009 10 x AWG 20 7,80 95,0 54,6 30160 / 30900 40025
compare  

Construction / data

Conductor

  • tinned stranded copper wire

Structure of conductor

Cross section

Core-Ø

AWG

number of cores

Core insulation

  • Semi-Rigid-PVC

Colour sequence

Twisting

  • cores in layers

Outer jacket

  • Special PVC, flame retardant acc. UL-VW-1

Outer jacket colour

  • black, sim. RAL 9005

Technical characteristics

Temperature range

  • static: -30 °C to +105 °C
  • dynamic: -15 °C to +105 °C
  • *UL 2517. Per UL 2464 only +80°C

Bending radius

  • > 15 x O.D.

Operating capacity (C/C)

Operating voltage

  • 300 V

Testing voltage

  • 1.500 V

Insulation resistance

  • > 100MOHM x km at + 20°C

Conductor resistance

Packaging

Rings at 100m, Reels at 500m
Lower and upper lengths according to availability. Special packaging on request.

Add-on information

Temperature rating per UL- Style 2464: 80°C; Style 2517: 105°C

Similar products