UL AWM Style 11030 - FRNC 90 V
  • installation
  • halogen free
  • FRNC
  • RoHS
  • REACH
  • CE

UL AWM Style 11030 - FRNC AWG 26/7

90 V
Order-No. 0892607

Application / Description

The mPPE-material allows very small outer diameters and don‘t contain softeners. Therefore it‘s an environment friendly replacement for PVC stranded wires. Stranded wires acc. to UL are primarily used for the internal wiring in electrical equipment as well as electrical control boxes and are steady to a large extent against acids, caustic solutions and many oils.

Variant data

O.D.

  • approx. 0,79 mm

weight

  • 1,0 kg/km

Cu-weigth

  • 0,9 kg/km

skinning tool

  • 40025 / 40026

Construction / data

Conductor

  • tinned stranded copper wire

Structure of conductor

  • 7 x 0,160 mm

Cross section

  • 0,14 qmm

Core insulation

  • mPPE

Conductor resistance

  • max. 150,0 Ohm/km

Dimension

  • AWG 26/7

Technical characteristics

Flamm­ability

  • flame retardant acc. to VW-1 (UL), FT-1 (cUL)

Temperature range

  • static: -40 °C to +105 °C
  • dynamic: -20 °C to +105 °C

Bending radius static

  • > 10 x O.D.

Bending radius dynamic

  • > 15 x O.D.

Operating voltage

  • 90 V

Testing voltage

  • 1.000 V

Insulation resistance

  • > 20 MOhm x km at + 20°C

Packaging

Spools at 250m
Lower and upper lengths according to availability. Special packaging on request.

Add-on information

Additional advantages of mPPE compared to PVC: small dielectric constant permits substantially smaller outside diameters, thereby weight saving; higher electrical strength; larger insulation resistance; FRNC, flame retardant, zero halogen;

 

Temperature rating per UL Style 11030 +105°C, cUL +105°C.

 

 

 