Application / Description

Stranded wires acc.  to UL are primarily used for the internal wiring in electrical equipment as well as electrical control boxes. Semi-Rigid-PVC as insulation material is to a large extent steady against acids, caustic solutions and many oils. This Style is, due to its structure of the conductor and insulation material suitable for the application in the gumption/clamping technology (LSA+).

Product range

Order-No.   Dimension   Conductor dimension qmm Structure of conductor mm O.D. approx. mm weight kg/km Cu-weigth kg/km skinning tool  
0912870 AWG 28/7 0,09 7 x 0,127 0,90 2,2 0,9 40025 / 40026
0912670 AWG 26/7 0,14 7 x 0,160 1,05 2,5 1,4 40025 / 40026
0912470 AWG 24/7 0,22 7 x 0,200 1,15 3,2 2,3 20100 / 40025
0912270 AWG 22/7 0,34 7 x 0,250 1,30 4,9 3,5 20100 / 40025
0912070 AWG 20/7 0,56 7 x 0,320 1,50 7,5 5,6 20100 / 40025
compare  

Construction / data

Conductor

  • tinned stranded copper wire

Core-Ø

AWG

Core insulation

  • Semi-Rigid-PVC

Technical characteristics

Temperature range

  • static: -30 °C to +105 °C
  • dynamic: -5 °C to +105 °C

Bending radius static

  • > 10 x O.D.

Bending radius dynamic

  • > 15 x O.D.

Operating voltage

  • 300 V

Testing voltage

  • 1.500 V

Insulation resistance

  • > 200 MOhm x km at + 20°C

Packaging

Spools at 500m
Lower and upper lengths according to availability. Special packaging on request.

Add-on information

Flammability: flame retardant acc. to VW-1 (UL), FT-1 (cUL)

Temperature rating per UL Style 1061 +80°C, Style 10002 +105°C, cUL +105°C

 

Colours

the following colors are deliverable:
black, white, red, blue, orange, yellow, green, brown

(further colors as well as 2-colored versions are available on request)