- installation
- halogen free
- FRNC
- RoHS
- REACH
- CE
- UN/ECE R118
Application / Description
The mPPE-material allows very small outer diameters and don‘t contain softeners. Therefore it‘s an environment
friendly replacement for PVC stranded wires. Stranded wires acc. to UL are primarily used for the internal wiring
in electrical equipment as well as electrical control boxes and are steady to a large extent against acids, caustic
solutions and many oils.
Variant data
O.D.
- approx. 1,15 mm
weight
- 2,0 kg/km
Cu-weigth
- 1,4 kg/km
skinning tool
- 20100 / 40025
Construction / data
Conductor
- tinned stranded copper wire
Structure of conductor
- 7 x 0,160 mm
Cross section
- 0,14 qmm
AWG
- 26-7
Core insulation
- mPPE
Dimension
- AWG 26/7
Technical characteristics
Flammability
- flame retardant acc. to VW-1 (UL), FT-1 (cUL)
Temperature range
- static: -40 °C to +105 °C
- dynamic: -20 °C to +105 °C
Bending radius static
- > 10 x O.D.
Bending radius dynamic
- > 15 x O.D.
Operating voltage
- 1.000 V
Testing voltage
- 3.000 V
Insulation resistance
- > 20 MOhm x km at + 20°C
Packaging
Spools at 250mLower and upper lengths according to availability. Special packaging on request.
Add-on information
Additional advantages of mPPE compared to PVC: small dielectric constant permits substantially smaller outside
diameters, thereby weight saving; higher electrical strength; larger insulation resistance; FRNC, flame retardant, zero halogen;
.
Temperature rating per UL Style 11029 +105°C, cUL +105°C