- installation
- halogen free
- FRNC
- RoHS
- REACH
- CE
Application / Description
Structured wiring in buildings acc. to ISO/IEC 11801 and EN 50173. Better than CAT 7 acc. to EN 50288 and IEC 61156. Low scew, pair- and total screen as well as a brilliant NEXT.
Product range
Order-No. | Dimension | O.D. approx. mm | weight kg/km | Cu-weigth kg/km | skinning tool (core) | skinning tool (jacket) |
---|---|---|---|---|---|---|
530802304 | 4 x 2 x AWG 23/1 | 8,00 | 70,0 | 38,0 | 30500 | 20100 |
Construction / network
Conductor
- bare solid copper wire
Structure of conductor
- 1x0,57 mm
AWG
- 23/1
Core insulation
- Cell-PE, Foam Skin
Pre-twisting
- cores to pairs
Element shield
- Al-Foil (PiMF)
Twisting
- pairs to the cable rope
Overall shield
- tinned copper braid
Outer jacket
- FRNC (LSZH)
Technical characteristics
Temperature range
- static: -20 °C to +60 °C
- dynamic: -5 °C to +50 °C
Bending radius static
- > 7 x O.D.
Bending radius dynamic
- > 8 x O.D.
Operating capacity (C/C)
- approx. 42 pF/m
Characteristic impedance
- 100 MHz: 100 ± 5 OHM
Attenuation
- 1 Mhz: approx. 1,9
db/100m
10 Mhz: approx. 4,8 db/100m
100 Mhz: approx. 16,4 db/100m
500 Mhz: approx. 38,2 db/100m
800 Mhz: approx. 50,8 db/100m
1000 Mhz: approx. 61,0 db/100m
Insulation resistance
- > 5 GOhm x km at + 20°C
Signal propragation time
- max. 420 ns/100 m
Delay time
- <5 ns / 100m @ 100MHz
Packaging
Rings, ReelsLower and upper lengths according to availability. Special packaging on request.