Stranded wires acc. to UL are primarily used for the internal wiring in electrical equipment as well as electrical control boxes. Semi-Rigid-PVC as insulation material is to a large extent steady against acids, caustic solutions and many oils. This Style is, due to its structure of the conductor and insulation material suitable for the application in the gumption/clamping technology (LSA+).
Variant data
O.D.
- approx. 1,15 mm
weight
- 3,2 kg/km
Cu-weigth
- 2,3 kg/km
skinning tool
- 20100 / 40025
Construction / data
Conductor
- tinned stranded copper wire
Structure of conductor
- 7 x 0,200 mm
Cross section
- 0,22 qmm
Core-Ø
- approx. 1,15 mm
AWG
- 24
Core insulation
- Semi-Rigid-PVC
Dimension
- AWG 24/7
Technical characteristics
Temperature range
- static: -30 °C to +105 °C
- dynamic: -5 °C to +105 °C
- *UL 10002. Nach UL 1061 nur bis +80°C
Bending radius static
- > 10 x O.D.
Bending radius dynamic
- > 15 x O.D.
Operating voltage
- 300 V
Testing voltage
- 1.500 V
Insulation resistance
- > 200 MOhm x km at + 20°C
Packaging
Spools at 500mLower and upper lengths according to availability. Special packaging on request.
Add-on information
Flammability: flame retardant acc. to VW-1 (UL), FT-1 (cUL)
Temperature rating per UL Style 1061 +80°C, Style 10002 +105°C, cUL +105°C
Colours
the following colors are deliverable:black, white, red, blue, orange, yellow, green, brown