UL-2-LiYCY twisted pair (TP)  UL AWM 2464/2517-10002, shielded
  • installation
  • mobile
  • RoHS
  • REACH
  • CE

UL-2-LiYCY twisted pair (TP)

UL AWM 2464/2517-10002, shielded

Application / Description

For connections in all fields of the measuring and control engineering as well as in signal and impulse technology. UL-specifications have to be matched for products which are exported to the American Market. Because of SR-PVC is used as core insulation, suitable for insulation displacement connectors (IDC). The outer jacket is to a very large extend resistant against oils, petrol, and weather-proof as well as UV-resistant by special PVC. The screening prevents electrical noice of influences to a large extend.

Product range

Order-No.   Dimension   O.D. approx. mm weight kg/km Cu-weigth kg/km skinning tool (core)   skinning tool (jacket)  
097042809 2 x 2 x AWG 28 5,20 35,2 14,3 20300 / 30160 40025
097062809 3 x 2 x AWG 28 5,50 38,7 16,1 20300 / 30160 40025
097082809 4 x 2 x AWG 28 5,90 44,7 19,6 20300 / 30160 40025
097122809 6 x 2 x AWG 28 6,90 60,8 27,4 20300 / 30160 40025
097162809 8 x 2 x AWG 28 7,50 70,9 29,5 30160 40025
097042609 2 x 2 x AWG 26 5,60 41,6 20,2 20310 / 30900 40025
097062609 3 x 2 x AWG 26 5,90 45,8 23,4 20310 / 20300 40025
097082609 4 x 2 x AWG 26 6,40 53,5 25,4 20300 / 30900 40025
097122609 6 x 2 x AWG 26 7,50 70,0 37,0 20330 / 30160 40025
097162609 8 x 2 x AWG 26 8,10 85,1 44,7 20330 / 30160 40025
097242609 12 x 2 x AWG 26 9,80 120,1 55,5 20300 / 30160 40025
compare  

Construction / data

Conductor

  • tinned stranded copper wire

Structure of conductor

Cross section

Core-Ø

AWG

Core insulation

  • Semi-Rigid-PVC

Colour sequence

Pre-twisting

  • 2 cores to a pair

Twisting

  • pairs to the cable rope

Overall shield

  • tinned copper braid, approx. 85% coverage, drain wire

Outer jacket

  • Special-PVC flame retardant acc. to UL-VW-1 conditionally resistant against oil and petrol

Outer jacket colour

  • black sim. RAL 9005

Technical characteristics

Temperature range

  • static: -30 °C to +105 °C
  • dynamic: -15 °C to +105 °C
  • *UL 2517. Per UL 2464 only +80°C

Bending radius static

  • > 10 x O.D.

Bending radius dynamic

  • > 15 x O.D.

Operating capacity (C/C)

Operating voltage

  • 300 V

Testing voltage

  • 1.500 V

Current capacity (at +25° C)

Insulation resistance

  • > 100 MOhm x km at + 20°C

Conductor resistance

Packaging

Rings at 100m, Reels at 500m
Lower and upper lengths according to availability. Special packaging on request.

Add-on information

Temperature rating per UL: Style 2464: 80°C; Style 2517: 105°C